KSB

12 products, 804 attributes mapped across 1 ETIM class. 94% coverage from public catalogs and spec sheets alone.

Products12

Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)12.5 m3/h m³/h
Discharge head at flow rate (BEP)200 kPa
Max. static height23.5 m
Max. discharge flow30 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current4.9 A
Motor power output (P2) per motor2.2 kW
Minimum Efficiency Index (MEI)0.4
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 50
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 32
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end125 mm
Height of pressure end125 mm
Length of centre pressure/suction connection250 mm
Pump length535 mm
Foundation plate length750 mm
Foundation plate width315 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)12.5 m3/h m³/h
Discharge head at flow rate (BEP)320 kPa
Max. static height38 m
Max. discharge flow30 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current6.5 A
Motor power output (P2) per motor3 kW
Minimum Efficiency Index (MEI)0.4
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 50
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 32
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end125 mm
Height of pressure end125 mm
Length of centre pressure/suction connection250 mm
Pump length610 mm
Foundation plate length850 mm
Foundation plate width315 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)25 m3/h m³/h
Discharge head at flow rate (BEP)280 kPa
Max. static height35 m
Max. discharge flow50 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current8.6 A
Motor power output (P2) per motor4 kW
Minimum Efficiency Index (MEI)0.45
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 65
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 40
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end160 mm
Height of pressure end160 mm
Length of centre pressure/suction connection280 mm
Pump length660 mm
Foundation plate length900 mm
Foundation plate width350 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)25 m3/h m³/h
Discharge head at flow rate (BEP)400 kPa
Max. static height50 m
Max. discharge flow50 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current11.5 A
Motor power output (P2) per motor5.5 kW
Minimum Efficiency Index (MEI)0.45
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 65
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 40
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end200 mm
Height of pressure end200 mm
Length of centre pressure/suction connection280 mm
Pump length715 mm
Foundation plate length950 mm
Foundation plate width350 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)50 m3/h m³/h
Discharge head at flow rate (BEP)350 kPa
Max. static height42 m
Max. discharge flow100 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current15.5 A
Motor power output (P2) per motor7.5 kW
Minimum Efficiency Index (MEI)0.5
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 80
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 50
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end200 mm
Height of pressure end200 mm
Length of centre pressure/suction connection350 mm
Pump length780 mm
Foundation plate length1050 mm
Foundation plate width400 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)50 m3/h m³/h
Discharge head at flow rate (BEP)250 kPa
Max. static height30 m
Max. discharge flow100 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current11.5 A
Motor power output (P2) per motor5.5 kW
Minimum Efficiency Index (MEI)0.5
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 80
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 65
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end160 mm
Height of pressure end160 mm
Length of centre pressure/suction connection350 mm
Pump length715 mm
Foundation plate length950 mm
Foundation plate width400 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)100 m3/h m³/h
Discharge head at flow rate (BEP)400 kPa
Max. static height50 m
Max. discharge flow200 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current29 A
Motor power output (P2) per motor15 kW
Minimum Efficiency Index (MEI)0.55
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 100
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 65
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end200 mm
Height of pressure end200 mm
Length of centre pressure/suction connection400 mm
Pump length880 mm
Foundation plate length1200 mm
Foundation plate width450 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)100 m3/h m³/h
Discharge head at flow rate (BEP)300 kPa
Max. static height38 m
Max. discharge flow200 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current22 A
Motor power output (P2) per motor11 kW
Minimum Efficiency Index (MEI)0.55
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 100
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 80
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end200 mm
Height of pressure end200 mm
Length of centre pressure/suction connection400 mm
Pump length830 mm
Foundation plate length1150 mm
Foundation plate width450 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)100 m3/h m³/h
Discharge head at flow rate (BEP)550 kPa
Max. static height65 m
Max. discharge flow200 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current42 A
Motor power output (P2) per motor22 kW
Minimum Efficiency Index (MEI)0.55
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 100
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 65
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end250 mm
Height of pressure end250 mm
Length of centre pressure/suction connection400 mm
Pump length950 mm
Foundation plate length1350 mm
Foundation plate width500 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)200 m3/h m³/h
Discharge head at flow rate (BEP)250 kPa
Max. static height30 m
Max. discharge flow400 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current36 A
Motor power output (P2) per motor18.5 kW
Minimum Efficiency Index (MEI)0.6
Insulation class according to IECF
Rotational speed1450 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 125
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 100
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end200 mm
Height of pressure end200 mm
Length of centre pressure/suction connection450 mm
Pump length920 mm
Foundation plate length1400 mm
Foundation plate width500 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)350 m3/h m³/h
Discharge head at flow rate (BEP)300 kPa
Max. static height40 m
Max. discharge flow640 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current57 A
Motor power output (P2) per motor30 kW
Minimum Efficiency Index (MEI)0.65
Insulation class according to IECF
Rotational speed1450 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 150
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 125
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end250 mm
Height of pressure end250 mm
Length of centre pressure/suction connection500 mm
Pump length1050 mm
Foundation plate length1550 mm
Foundation plate width550 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3
Material pump casingCast iron
Material quality pump casingCast iron EN-GJL-250 (GG 25)
Material impeller/pump wheelCast iron
Material quality impeller/pump wheelCast iron EN-GJL-250 (GG 25)
Volume flow rate (BEP)50 m3/h m³/h
Discharge head at flow rate (BEP)550 kPa
Max. static height65 m
Max. discharge flow100 m3/h m³/h
Max. operating pressure16 bar
Electrical connectionTerminals
Rated voltage380-420 V
Number of phases3
Frequency50/60 Hz
Nominal current29 A
Motor power output (P2) per motor15 kW
Minimum Efficiency Index (MEI)0.5
Insulation class according to IECF
Rotational speed2900 1/min
Motor speed controlNone
CommunicationNone
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Mobile communications standard 2G (GSM)No
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Mobile communications standard 5GNo
Interface signal 0-10 V / 2-10 VNo
Interface signal 0-20 mA / 4-20 mANo
Interface PT100 / PT1000 / PTCNo
Interface Pulse Width Modulation (PWM)No
Interface pulse counterNo
Potential free switch contactNo
With communication interface RS-485No
With communication interface RS-232No
Supporting protocol for EtherNet/IPNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Supporting protocol for PROFINET IONo
Supporting protocol for CAN/CANOpenNo
Supporting protocol for Modbus TCPNo
Supporting protocol for Modbus RTUNo
Supporting protocol for BACnet MS/TPNo
Supporting protocol for BACnet IPNo
Supporting protocol for LON/LONWorksNo
Supporting protocol for LIN BusNo
Medium temperature (continuous)-30 to 140 °C
Ambient temperature-20 to 40 °C
Connection inlet sideFlange
Nominal diameter connection inlet sideDN 80
Flange compression stage connection inlet sidePN 16
Connection standard inlet sideEN 1092-1
Connection outlet sideFlange
Nominal diameter connection outlet sideDN 50
Flange compression stage connection outlet sidePN 16
Connection standard outlet sideEN 1092-1
Flange shapeRound
Degree of protection (IP)IP54
Forced motor coolingYes
Height of suction end250 mm
Height of pressure end250 mm
Length of centre pressure/suction connection350 mm
Pump length880 mm
Foundation plate length1150 mm
Foundation plate width400 mm
Explosion-proofNo
Standard motorYes
Motor efficiency classIE3

Built by rastro.ai