Murrelektronik
25 products, 723 attributes mapped across 10 ETIM classes. 65% coverage from public catalogs and spec sheets alone.
Products15
Supply voltage DC24 to 24 V
Voltage type (supply voltage)DC
Number of HW-interfaces industrial Ethernet1
Number of interfaces PROFINET1
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces wireless0
Number of HW-interfaces USB0
Number of HW-interfaces other0
With optical interfacefalse
Supporting protocol for EtherCATfalse
Supporting protocol for TCP/IPtrue
Supporting protocol for PROFIBUSfalse
Supporting protocol for CANfalse
Supporting protocol for INTERBUSfalse
Supporting protocol for ASIfalse
Supporting protocol for KNXfalse
Supporting protocol for Modbusfalse
Supporting protocol for Data-Highwayfalse
Supporting protocol for DeviceNetfalse
Supporting protocol for SUCONETfalse
Supporting protocol for LONfalse
Supporting protocol for PROFINET IOtrue
Supporting protocol for PROFINET CBAfalse
Supporting protocol for SERCOSfalse
Supporting protocol for Foundation Fieldbusfalse
Supporting protocol for EtherNet/IPfalse
Supporting protocol for AS-Interface Safety at Workfalse
Supporting protocol for DeviceNet Safetyfalse
Supporting protocol for INTERBUS-Safetyfalse
Supporting protocol for PROFIsafefalse
Supporting protocol for SafetyBUS pfalse
Supporting protocol for other bus systemsfalse
Radio standard Bluetoothfalse
Radio standard WLAN 802.11false
Radio standard GPRSfalse
Radio standard GSMfalse
Mobile communications standard 3G (UMTS)false
IO link mastertrue
System accessoryfalse
Suitable for countingfalse
Suitable for weighingfalse
Suitable for temperature controlfalse
Suitable for welding controlfalse
Suitable for pressure controlfalse
Suitable for NCfalse
Suitable for electronic positioningfalse
Suitable for CNCfalse
Suitable for SSIfalse
Suitable for incremental data detectionfalse
Suitable for detection absolute valuefalse
Suitable for flux controllerfalse
Suitable for flux measurementfalse
Suitable for path controllerfalse
Suitable for cam controllerfalse
Suitable for flying sawfalse
Suitable for multi-axis controlfalse
Suitable for single-axis controllerfalse
Suitable for multi-axis positioningfalse
Suitable for single-axis positioningfalse
Function block restart blockagefalse
Function block automatic resetfalse
Contactor control function blockfalse
Function block emergency stopfalse
Function block contactless working protection installationfalse
Function block affirm push buttonfalse
Function block 2-hand switchingfalse
Function block operating mode selectionfalse
Function block access controlfalse
Degree of protection (IP)IP67
Fieldbus connection over separate bus coupler possiblefalse
Frequency measurementfalse
Suitable for rail mountingfalse
Wall mounting/direct mountingtrue
Front built-in possiblefalse
Rack-assembly possiblefalse
Suitable for safety functionsfalse
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1Level e
Appendant operation agent (Ex ia)false
Appendant operation agent (Ex ib)false
Explosion safety category for gasNone
Explosion safety category for dustNone
Supply voltage DC24 to 24 V
Voltage type (supply voltage)DC
Number of HW-interfaces industrial Ethernet0
Number of interfaces PROFINET0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces wireless0
Number of HW-interfaces USB0
Number of HW-interfaces other0
With optical interfacefalse
Supporting protocol for EtherCATfalse
Supporting protocol for TCP/IPfalse
Supporting protocol for PROFIBUSfalse
Supporting protocol for CANfalse
Supporting protocol for INTERBUSfalse
Supporting protocol for ASIfalse
Supporting protocol for KNXfalse
Supporting protocol for Modbusfalse
Supporting protocol for Data-Highwayfalse
Supporting protocol for DeviceNetfalse
Supporting protocol for SUCONETfalse
Supporting protocol for LONfalse
Supporting protocol for PROFINET IOfalse
Supporting protocol for PROFINET CBAfalse
Supporting protocol for SERCOSfalse
Supporting protocol for Foundation Fieldbusfalse
Supporting protocol for EtherNet/IPfalse
Supporting protocol for AS-Interface Safety at Workfalse
Supporting protocol for DeviceNet Safetyfalse
Supporting protocol for INTERBUS-Safetyfalse
Supporting protocol for PROFIsafefalse
Supporting protocol for SafetyBUS pfalse
Supporting protocol for other bus systemsfalse
Radio standard Bluetoothfalse
Radio standard WLAN 802.11false
Radio standard GPRSfalse
Radio standard GSMfalse
Mobile communications standard 3G (UMTS)false
IO link mastertrue
System accessorytrue
Suitable for countingfalse
Suitable for weighingfalse
Suitable for temperature controlfalse
Suitable for welding controlfalse
Suitable for pressure controlfalse
Suitable for NCfalse
Suitable for electronic positioningfalse
Suitable for CNCfalse
Suitable for SSIfalse
Suitable for incremental data detectionfalse
Suitable for detection absolute valuefalse
Suitable for flux controllerfalse
Suitable for flux measurementfalse
Suitable for path controllerfalse
Suitable for cam controllerfalse
Suitable for flying sawfalse
Suitable for multi-axis controlfalse
Suitable for single-axis controllerfalse
Suitable for multi-axis positioningfalse
Suitable for single-axis positioningfalse
Function block restart blockagefalse
Function block automatic resetfalse
Contactor control function blockfalse
Function block emergency stopfalse
Function block contactless working protection installationfalse
Function block affirm push buttonfalse
Function block 2-hand switchingfalse
Function block operating mode selectionfalse
Function block access controlfalse
Degree of protection (IP)IP67
Fieldbus connection over separate bus coupler possiblefalse
Frequency measurementfalse
Suitable for rail mountingfalse
Wall mounting/direct mountingtrue
Front built-in possiblefalse
Rack-assembly possiblefalse
Suitable for safety functionsfalse
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)false
Appendant operation agent (Ex ib)false
Explosion safety category for gasNone
Explosion safety category for dustNone
With integrated power supplyfalse
Input voltage DC24 to 24 V
Type of voltage (input voltage)DC
Max. input current DC0.12 A
Number of HW-interfaces industrial Ethernet2
Number of interfaces PROFINET2
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces USB0
Number of HW-interfaces parallel0
Number of HW-interfaces wireless0
Number of HW-interfaces other0
With optical interfacefalse
Supporting protocol for EtherCATfalse
Supporting protocol for TCP/IPtrue
Supporting protocol for PROFIBUSfalse
Supporting protocol for CANfalse
Supporting protocol for INTERBUSfalse
Supporting protocol for ASIfalse
Supporting protocol for KNXfalse
Supporting protocol for Modbusfalse
Supporting protocol for Data-Highwayfalse
Supporting protocol for DeviceNetfalse
Supporting protocol for SUCONETfalse
Supporting protocol for LONfalse
Supporting protocol for SERCOSfalse
Supporting protocol for PROFINET IOtrue
Supporting protocol for PROFINET CBAfalse
Supporting protocol for Foundation Fieldbusfalse
Supporting protocol for EtherNet/IPfalse
Supporting protocol for AS-Interface Safety at Workfalse
Supporting protocol for DeviceNet Safetyfalse
Supporting protocol for INTERBUS-Safetyfalse
Supporting protocol for PROFIsafefalse
Supporting protocol for SafetyBUS pfalse
Supporting protocol for other bus systemsfalse
Radio standard Bluetoothfalse
Radio standard WLAN 802.11false
Radio standard GPRSfalse
Radio standard GSMfalse
Mobile communications standard 3G (UMTS)false
IO link masterfalse
System accessoryfalse
Degree of protection (IP)IP67
Number of slots32
With pluggable modules, digital I/Otrue
With pluggable modules, analogue I/Otrue
With pluggable modules, communication modulestrue
With pluggable modules, function and technology modulestrue
With pluggable modules, central modulesfalse
With pluggable modules, othersfalse
With potential separationfalse
Fieldbus connection over separate bus coupler possiblefalse
With bus coupler for modular station connectionfalse
Suitable for rail mountingfalse
Wall mounting/direct mountingtrue
Front built-in possiblefalse
Rack-assembly possiblefalse
Suitable for safety functionsfalse
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)false
Appendant operation agent (Ex ib)false
Explosion safety category for gasNone
Explosion safety category for dustNone
Certified for UL hazardous location class Ifalse
Certified for UL hazardous location class IIfalse
Certified for UL hazardous location class IIIfalse
Certified for UL hazardous location division 1false
Certified for UL hazardous location division 2false
Certified for UL hazardous location group A (acetylene)false
Certified for UL hazardous location group B (hydrogen)false
Certified for UL hazardous location group C (ethylene)false
Certified for UL hazardous location group D (propane)false
Certified for UL hazardous location group E (metal dusts)false
Certified for UL hazardous location group F (carbonaceous dusts)false
Certified for UL hazardous location group G (non-conductive dusts)false
Number of analogue inputs4
Number of analogue outputs0
Analogue inputs configurablefalse
Number of digital inputs4
Number of digital outputs4
Supply voltage DC24 to 24 V
Voltage type (supply voltage)DC
Permitted voltage at input0 to 10 V
Type of voltage (input voltage)DC
Type of digital outputTransistor
Type of output voltageDC
Analogue input, currentfalse
Analogue input, voltagetrue
Analogue input, resistorfalse
Analogue input, resistor temperaturefalse
Analogue input, thermocouplefalse
Resolution of the analogue inputs16 Bit
Analogue input signal configurablefalse
Analogue output, currentfalse
Analogue output, voltagefalse
Number of HW-interfaces industrial Ethernet0
Number of interfaces PROFINET0
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces wireless0
Number of HW-interfaces USB0
Number of HW-interfaces other0
With optical interfacefalse
Supporting protocol for EtherCATfalse
Supporting protocol for TCP/IPfalse
Supporting protocol for PROFIBUStrue
Supporting protocol for CANfalse
Supporting protocol for INTERBUSfalse
Supporting protocol for ASIfalse
Supporting protocol for KNXfalse
Supporting protocol for Modbusfalse
Supporting protocol for Data-Highwayfalse
Supporting protocol for DeviceNetfalse
Supporting protocol for SUCONETfalse
Supporting protocol for LONfalse
Supporting protocol for PROFINET IOfalse
Supporting protocol for PROFINET CBAfalse
Supporting protocol for SERCOSfalse
Supporting protocol for Foundation Fieldbusfalse
Supporting protocol for EtherNet/IPfalse
Supporting protocol for AS-Interface Safety at Workfalse
Supporting protocol for DeviceNet Safetyfalse
Supporting protocol for INTERBUS-Safetyfalse
Supporting protocol for PROFIsafefalse
Supporting protocol for SafetyBUS pfalse
Supporting protocol for other bus systemsfalse
Radio standard Bluetoothfalse
Radio standard WLAN 802.11false
Radio standard GPRSfalse
Radio standard GSMfalse
Mobile communications standard 3G (UMTS)false
IO link masterfalse
System accessoryfalse
Degree of protection (IP)IP67
Fieldbus connection over separate bus coupler possiblefalse
Suitable for rail mountingfalse
Wall mounting/direct mountingtrue
Front built-in possiblefalse
Rack-assembly possiblefalse
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1Level e
Suitable for safety functionsfalse
Appendant operation agent (Ex ia)false
Appendant operation agent (Ex ib)false
Explosion safety category for gasNone
Explosion safety category for dustNone
Supply voltage DC24 to 24 V
Voltage type (supply voltage)DC
Input, currentfalse
Input, voltagetrue
Input, resistorfalse
Input, resistance thermometerfalse
Input, thermocouplefalse
Input signal, configurablefalse
Resolution of the analogue inputs15 Bit
Output, currentfalse
Output, voltagefalse
Output signal configurablefalse
Number of analogue inputs4
Number of analogue outputs0
Analogue inputs configurablefalse
Supporting protocol for EtherCATfalse
Supporting protocol for TCP/IPfalse
Supporting protocol for PROFIBUSfalse
Supporting protocol for CANfalse
Supporting protocol for INTERBUSfalse
Supporting protocol for ASIfalse
Supporting protocol for KNXfalse
Supporting protocol for Modbusfalse
Supporting protocol for Data-Highwayfalse
Supporting protocol for DeviceNetfalse
Supporting protocol for SUCONETfalse
Supporting protocol for LONfalse
Supporting protocol for PROFINET IOfalse
Supporting protocol for PROFINET CBAfalse
Supporting protocol for SERCOSfalse
Supporting protocol for Foundation Fieldbusfalse
Supporting protocol for EtherNet/IPfalse
Supporting protocol for AS-Interface Safety at Workfalse
Supporting protocol for DeviceNet Safetyfalse
Supporting protocol for INTERBUS-Safetyfalse
Supporting protocol for PROFIsafefalse
Supporting protocol for SafetyBUS pfalse
Supporting protocol for other bus systemsfalse
Radio standard Bluetoothfalse
Radio standard WLAN 802.11false
Radio standard GPRSfalse
Radio standard GSMfalse
Mobile communications standard 3G (UMTS)false
IO link masterfalse
System accessorytrue
Degree of protection (IP)IP67
Fieldbus connection over separate bus coupler possiblefalse
Suitable for rail mountingfalse
Wall mounting/direct mountingtrue
Front built-in possiblefalse
Rack-assembly possiblefalse
Suitable for safety functionsfalse
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)false
Appendant operation agent (Ex ib)false
Explosion safety category for gasNone
Explosion safety category for dustNone
Certified for UL hazardous location class Ifalse
Certified for UL hazardous location class IIfalse
Certified for UL hazardous location class IIIfalse
Certified for UL hazardous location division 1false
Certified for UL hazardous location division 2false
Certified for UL hazardous location group A (acetylene)false
Certified for UL hazardous location group B (hydrogen)false
Certified for UL hazardous location group C (ethylene)false
Certified for UL hazardous location group D (propane)false
Certified for UL hazardous location group E (metal dusts)false
Certified for UL hazardous location group F (carbonaceous dusts)false
Certified for UL hazardous location group G (non-conductive dusts)false
Supply voltage DC24 to 24 V
Number of digital inputs8
Number of digital outputs8
Type of voltage (input voltage)DC
Type of digital outputTransistor
Output current2 A
Type of output voltageDC
Number of HW-interfaces industrial Ethernet2
Number of interfaces PROFINET2
Number of HW-interfaces RS-2320
Number of HW-interfaces RS-4220
Number of HW-interfaces RS-4850
Number of HW-interfaces serial TTY0
Number of HW-interfaces parallel0
Number of HW-interfaces wireless0
Number of HW-interfaces USB0
Number of HW-interfaces other0
With optical interfacefalse
Supporting protocol for EtherCATfalse
Supporting protocol for TCP/IPfalse
Supporting protocol for PROFIBUSfalse
Supporting protocol for CANfalse
Supporting protocol for INTERBUSfalse
Supporting protocol for ASIfalse
Supporting protocol for KNXfalse
Supporting protocol for Modbusfalse
Supporting protocol for Data-Highwayfalse
Supporting protocol for DeviceNetfalse
Supporting protocol for SUCONETfalse
Supporting protocol for LONfalse
Supporting protocol for PROFINET IOtrue
Supporting protocol for PROFINET CBAfalse
Supporting protocol for SERCOSfalse
Supporting protocol for Foundation Fieldbusfalse
Supporting protocol for EtherNet/IPfalse
Supporting protocol for AS-Interface Safety at Workfalse
Supporting protocol for DeviceNet Safetyfalse
Supporting protocol for INTERBUS-Safetyfalse
Supporting protocol for PROFIsafefalse
Supporting protocol for SafetyBUS pfalse
Supporting protocol for other bus systemsfalse
Radio standard Bluetoothfalse
Radio standard WLAN 802.11false
Radio standard GPRSfalse
Radio standard GSMfalse
Mobile communications standard 3G (UMTS)false
IO link masterfalse
System accessoryfalse
Degree of protection (IP)IP67
Fieldbus connection over separate bus coupler possiblefalse
Suitable for rail mountingfalse
Wall mounting/direct mountingtrue
Front built-in possiblefalse
Rack-assembly possiblefalse
Suitable for safety functionsfalse
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1Level e
Appendant operation agent (Ex ia)false
Appendant operation agent (Ex ib)false
Explosion safety category for gasNone
Explosion safety category for dustNone
Voltage type (supply voltage)AC
1st secondary output voltage24 to 24 V
Max. output current 110 A
Secondary voltage adjustablefalse
Nominal value output voltage 124 V
Nominal value output current 110 A
Short-circuit-prooftrue
Rated supply voltage AC 50 Hz90 to 264 V
Rated supply voltage AC 60 Hz90 to 264 V
Output voltage stabilizedtrue
Power output240 W
Stabilizedtrue
Suitable for rail mountingtrue
Suitable for wall mountingfalse
Suitable for distribution boardfalse
Built-in width85 mm
Built-in height125 mm
Width85 mm
Height125 mm
Voltage type (supply voltage)AC
1st secondary output voltage24 to 24 V
Max. output current 15 A
Secondary voltage adjustablefalse
Nominal value output voltage 124 V
Nominal value output current 15 A
Short-circuit-prooftrue
Rated supply voltage AC 50 Hz85 to 265 V
Rated supply voltage AC 60 Hz85 to 265 V
Output voltage stabilizedtrue
Power output120 W
Stabilizedtrue
Suitable for rail mountingtrue
Suitable for wall mountingfalse
Suitable for distribution boardfalse
Built-in width50 mm
Width50 mm
Voltage type (supply voltage)AC
1st secondary output voltage24 to 24 V
Max. output current 111.8 A
Secondary voltage adjustablefalse
Nominal value output voltage 124 V
Nominal value output current 111.8 A
Short-circuit-prooftrue
Rated supply voltage AC 50 Hz85 to 265 V
Rated supply voltage AC 60 Hz85 to 265 V
Output voltage stabilizedtrue
Power output283 W
Stabilizedtrue
Suitable for rail mountingtrue
Suitable for wall mountingfalse
Suitable for distribution boardfalse
Built-in width65 mm
Width65 mm
Voltage type (supply voltage)AC
1st secondary output voltage24 to 24 V
Max. output current 120 A
Secondary voltage adjustablefalse
Nominal value output voltage 124 V
Nominal value output current 120 A
Short-circuit-prooftrue
Rated supply voltage AC 50 Hz90 to 265 V
Rated supply voltage AC 60 Hz90 to 265 V
Output voltage stabilizedtrue
Power output480 W
Stabilizedtrue
Suitable for rail mountingtrue
Suitable for wall mountingfalse
Suitable for distribution boardfalse
Built-in width85 mm
Width85 mm
Voltage type (supply voltage)AC
1st secondary output voltage24 to 24 V
Max. output current 140 A
Secondary voltage adjustablefalse
Nominal value output voltage 124 V
Nominal value output current 140 A
Short-circuit-prooftrue
Rated supply voltage AC 50 Hz324 to 572 V
Rated supply voltage AC 60 Hz324 to 572 V
Output voltage stabilizedtrue
Power output960 W
Stabilizedtrue
Suitable for rail mountingtrue
Suitable for wall mountingfalse
Suitable for distribution boardfalse
Built-in width109 mm
Width109 mm
Voltage type (supply voltage)AC
1st secondary output voltage24 to 24 V
Max. output current 12.5 A
Secondary voltage adjustablefalse
Nominal value output voltage 124 V
Nominal value output current 12.5 A
Short-circuit-prooftrue
Rated supply voltage AC 50 Hz100 to 240 V
Rated supply voltage AC 60 Hz100 to 240 V
Output voltage stabilizedtrue
Power output60 W
Stabilizedtrue
Suitable for rail mountingtrue
Suitable for wall mountingfalse
Suitable for distribution boardfalse
Built-in width50 mm
Width50 mm
Voltage type (supply voltage)AC
1st secondary output voltage24 to 24 V
Max. output current 15 A
Secondary voltage adjustablefalse
Nominal value output voltage 124 V
Nominal value output current 15 A
Short-circuit-prooftrue
Rated supply voltage AC 50 Hz90 to 264 V
Rated supply voltage AC 60 Hz90 to 264 V
Output voltage stabilizedtrue
Power output120 W
Stabilizedtrue
Suitable for rail mountingtrue
Suitable for wall mountingfalse
Suitable for distribution boardfalse
Built-in width50 mm
Width50 mm
Number of poles4
Cable length5000 mm
Type of plug-in contact, outer sideNone
Type of plug-in contact, inner sideFemale (bus)
Number of power contacts4
Coating housingNickel-plated
Material core insulationPolyurethane (PUR)
Ambient temperature-25 to 85 °C
Operating temperature-25 to 85 °C
Rated voltage63 V
Rated current In12 A
With shield connectionfalse
Screw-in threadM12
Core cross section1.5 mm²
With PE-connectiontrue
Degree of protection (IP), mountedIP67
Number of poles4
Cable length10000 mm
Type of plug-in contact, outer sideNone
Type of plug-in contact, inner sideFemale (bus)
Coating housingUncoated
Material core insulationPolyvinyl chloride (PVC)
Ambient temperature-25 to 80 °C
Operating temperature-25 to 80 °C
Rated voltage250 V
Rated current In4 A
With shield connectionfalse
Screw-in threadM12
Core cross section0.34 mm²
With PE-connectionfalse
Degree of protection (IP), mountedIP67