Pepperl+Fuchs
17 products, 432 attributes mapped across 1 ETIM class. 71% coverage from public catalogs and spec sheets alone.
Products15
Diameter sensor12 mm
Mechanical mounting condition for sensorConcise
Switching distance2 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency1500 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor12 mm
Mechanical mounting condition for sensorConcise
Switching distance4 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage7-30 V
Rated control supply voltage DC7-30 V
Voltage typeDC
Switching frequency2200 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor18 mm
Mechanical mounting condition for sensorConcise
Switching distance5 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency800 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor30 mm
Mechanical mounting condition for sensorConcise
Switching distance10 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingOther
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency10 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor30 mm
Mechanical mounting condition for sensorConcise
Switching distance15 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency200 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor12 mm
Mechanical mounting condition for sensorConcise
Switching distance4 mm
Suitable for safety functionsNo
Type of switch functionChange-over contact (NO/NC)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function2
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs2
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency1500 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor12 mm
Mechanical mounting condition for sensorNot flat
Switching distance4 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency1200 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor18 mm
Mechanical mounting condition for sensorNot flat
Switching distance8 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingOther
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency500 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor12 mm
Mechanical mounting condition for sensorConcise
Switching distance2 mm
Suitable for safety functionsNo
Type of switch functionBreaker contact (NC)
Type of switching outputNPN
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency1500 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor30 mm
Mechanical mounting condition for sensorNot flat
Switching distance15 mm
Suitable for safety functionsNo
Type of switch functionChange-over contact (NO/NC)
Type of switching outputPNP/NPN
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function2
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs2
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage7-30 V
Rated control supply voltage DC7-30 V
Voltage typeDC
Switching frequency450 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor12 mm
Mechanical mounting condition for sensorNot flat
Switching distance8 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency1500 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor18 mm
Mechanical mounting condition for sensorConcise
Switching distance12 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
Coating housingNickel-plated
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency500 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Mechanical mounting condition for sensorConcise
Switching distance20 mm
Suitable for safety functionsNo
Type of switch functionNormally open contact (NO)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs1
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCuboid
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency440 Hz
Housing materialPlastic
Explosion safety category for gasNone
Explosion safety category for dustNone
Mechanical mounting condition for sensorNot flat
Switching distance40 mm
Suitable for safety functionsNo
Type of switch functionChange-over contact (NO/NC)
Type of switching outputPNP
Type of electric connectionConnector M12
Number of semiconductor outputs with signalling function2
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs2
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCuboid
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Max. output current at protected output200 mA
Supply voltage10-30 V
Rated control supply voltage DC10-30 V
Voltage typeDC
Switching frequency180 Hz
Housing materialPlastic
Explosion safety category for gasNone
Explosion safety category for dustNone
Diameter sensor18 mm
Mechanical mounting condition for sensorConcise
Switching distance5 mm
Suitable for safety functionsYes
Type of switch functionBreaker contact (NC)
Type of switching outputNAMUR
Type of electric connectionCable
Number of semiconductor outputs with signalling function1
Number of contact energized outputs with signalling function0
Number of protected semiconductor outputs0
Number of protected contact energized outputs0
Type of actuationMetallic Target
Type of interfaceNone
Type of interface for safety communicationNone
Construction type housingCylinder, screw-thread
SIL according to IEC 615082
Performance level according to EN ISO 13849-1None
Supply voltage5-25 V
Rated control supply voltage DC5-25 V
Voltage typeDC
Switching frequency500 Hz
Housing materialMetal
Explosion safety category for gasNone
Explosion safety category for dustNone
Built by rastro.ai