Pilz
25 products, 739 attributes mapped across 2 ETIM classes. 63% coverage from public catalogs and spec sheets alone.
Products15
Suitable for rail mountingtrue
Voltage type (supply voltage)AC/DC
Supply voltage AC 50 Hz24 to 24 V
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmentfalse
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs2-channel
Power consumption9 W
With start inputtrue
With muting functionfalse
With feedback circuittrue
Type of control voltage 1AC/DC
Control voltage 124 to 24 V
Number of outputs, safety related, undelayed, with contact7
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors2
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Voltage type (operating voltage)AC/DC
Operating voltage AC 50 Hz24 to 24 V
Operating voltage DC24 to 24 V
Rated switch current8 A
Type of safety according to IEC 61496-1None
Width90 mm
Height87 mm
Depth121 mm
Suitable for rail mountingtrue
Voltage type (supply voltage)AC/DC
Supply voltage AC 50 Hz24 to 24 V
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmentfalse
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs2-channel
Power consumption2 W
With start inputtrue
With muting functionfalse
With feedback circuittrue
Type of control voltage 1AC/DC
Control voltage 124 to 24 V
Number of outputs, safety related, undelayed, with contact3
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors0
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact0
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Voltage type (operating voltage)AC/DC
Operating voltage AC 50 Hz24 to 24 V
Operating voltage DC24 to 24 V
Rated switch current8 A
Type of safety according to IEC 61496-1None
Width45 mm
Height87 mm
Depth121 mm
Suitable for rail mountingtrue
Voltage type (supply voltage)AC/DC
Supply voltage AC 50 Hz24 to 24 V
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmentfalse
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs2-channel
Power consumption5 W
With start inputtrue
With muting functionfalse
With feedback circuittrue
Type of control voltage 1AC/DC
Control voltage 124 to 24 V
Number of outputs, safety related, undelayed, with contact3
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors1
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Voltage type (operating voltage)AC/DC
Operating voltage AC 50 Hz24 to 24 V
Operating voltage DC24 to 24 V
Type of safety according to IEC 61496-1None
Width45 mm
Height101 mm
Depth121 mm
Suitable for rail mountingtrue
Voltage type (supply voltage)AC/DC
Supply voltage AC 50 Hz24 to 24 V
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmentfalse
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs2-channel
Power consumption2 W
With start inputtrue
With muting functionfalse
With feedback circuittrue
Type of control voltage 1AC/DC
Control voltage 124 to 24 V
Number of outputs, safety related, undelayed, with contact2
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors0
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact0
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Voltage type (operating voltage)AC/DC
Operating voltage AC 50 Hz24 to 24 V
Operating voltage DC24 to 24 V
Type of safety according to IEC 61496-1None
Width22.5 mm
Height94 mm
Depth121 mm
Suitable for rail mountingtrue
With detachable clampsfalse
Type of electric connectionScrew connection
Voltage type (supply voltage)DC
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchesfalse
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmenttrue
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs1-channel
Power consumption2 W
With start inputtrue
With muting functionfalse
With feedback circuitfalse
Number of outputs, safety related, undelayed, with contact2
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors1
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact0
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Rated switch current3 A
Type of safety according to IEC 61496-1None
Performance level according to EN ISO 13849-1Level c
SIL according to IEC 615082
Width12.5 mm
Height98 mm
Depth120 mm
Suitable for rail mountingtrue
With detachable clampsfalse
Type of electric connectionSpring clamp connection
Voltage type (supply voltage)DC
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchesfalse
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmentfalse
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs1-channel
Power consumption2 W
With start inputtrue
With muting functionfalse
With feedback circuitfalse
Number of outputs, safety related, undelayed, with contact2
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors1
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact0
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Rated switch current3 A
Type of safety according to IEC 61496-1None
Performance level according to EN ISO 13849-1Level c
SIL according to IEC 615082
Width12.5 mm
Height100 mm
Depth120 mm
Suitable for rail mountingtrue
With detachable clampsfalse
Type of electric connectionScrew connection
Voltage type (supply voltage)DC
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmenttrue
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs2-channel
Power consumption4 W
With start inputtrue
With muting functionfalse
With feedback circuitfalse
Release-delay0.04 to 300 s
Number of outputs, safety related, undelayed, with contact2
Number of outputs, safety related, delayed, with contact2
Number of outputs, safety related, undelayed, semiconductors0
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact0
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Rated switch current6 A
Type of safety according to IEC 61496-1None
Performance level according to EN ISO 13849-1Level e
SIL according to IEC 615083
Width22.5 mm
Height98 mm
Suitable for rail mountingtrue
Voltage type (supply voltage)DC
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmentfalse
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs2-channel
Power consumption4.5 W
With start inputtrue
With muting functionfalse
With feedback circuittrue
Type of control voltage 1DC
Control voltage 124 to 24 V
Number of outputs, safety related, undelayed, with contact5
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors0
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Voltage type (operating voltage)DC
Operating voltage DC24 to 24 V
Rated switch current8 A
Type of safety according to IEC 61496-1None
Width45 mm
Height87 mm
Depth121 mm
Suitable for rail mountingtrue
Voltage type (supply voltage)AC
Supply voltage AC 50 Hz230 to 230 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmentfalse
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs1-channel
Power consumption5 W
With start inputtrue
With muting functionfalse
With feedback circuittrue
Type of control voltage 1AC
Control voltage 1230 to 230 V
Number of outputs, safety related, undelayed, with contact3
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors0
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Voltage type (operating voltage)AC
Operating voltage AC 50 Hz230 to 230 V
Rated switch current8 A
Type of safety according to IEC 61496-1None
Width90 mm
Height87 mm
Depth121 mm
Suitable for rail mountingtrue
Type of electric connectionPlug-in connection
Voltage type (supply voltage)DC
Supply voltage DC24 to 30 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmentfalse
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs2-channel
With start inputtrue
With muting functionfalse
With feedback circuittrue
Release-delay0 to 30 s
Type of control voltage 1DC
Control voltage 124 to 30 V
Number of outputs, safety related, undelayed, with contact3
Number of outputs, safety related, delayed, with contact2
Number of outputs, safety related, undelayed, semiconductors0
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Voltage type (operating voltage)DC
Operating voltage DC24 to 30 V
Type of safety according to IEC 61496-1None
Width45 mm
Height87 mm
Depth121 mm
Suitable for rail mountingtrue
With detachable clampsfalse
Voltage type (supply voltage)DC
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmentfalse
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs2-channel
Power consumption2.5 W
With start inputtrue
With muting functionfalse
With feedback circuitfalse
Type of control voltage 1DC
Control voltage 124 to 24 V
Number of outputs, safety related, undelayed, with contact3
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors0
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Voltage type (operating voltage)DC
Operating voltage DC24 to 24 V
Rated switch current6 A
Width22.5 mm
Height105 mm
Depth100 mm
Suitable for rail mountingtrue
With detachable clampsfalse
Type of electric connectionScrew connection
Voltage type (supply voltage)DC
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmenttrue
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs1-channel
Power consumption2 W
With start inputtrue
With muting functionfalse
With feedback circuitfalse
Number of outputs, safety related, undelayed, with contact3
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors1
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Rated switch current6 A
Type of safety according to IEC 61496-1None
Performance level according to EN ISO 13849-1Level e
SIL according to IEC 615083
Width17.5 mm
Height98 mm
Suitable for rail mountingtrue
With detachable clampsfalse
Type of electric connectionSpring clamp connection
Voltage type (supply voltage)DC
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmenttrue
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputs1-channel
Power consumption2 W
With start inputtrue
With muting functionfalse
With feedback circuitfalse
Number of outputs, safety related, undelayed, with contact3
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors1
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Rated switch current6 A
Type of safety according to IEC 61496-1None
Performance level according to EN ISO 13849-1Level e
SIL according to IEC 615083
Width17.5 mm
Height100 mm
Suitable for rail mountingtrue
With detachable clampsfalse
Type of electric connectionScrew connection
Voltage type (supply voltage)DC
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmenttrue
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputsOne- and two-channel
Power consumption2.5 W
With start inputtrue
With muting functionfalse
With feedback circuitfalse
Number of outputs, safety related, undelayed, with contact2
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors1
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact0
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Rated switch current6 A
Type of safety according to IEC 61496-1None
Performance level according to EN ISO 13849-1Level e
SIL according to IEC 615083
Width17.5 mm
Height98 mm
Suitable for rail mountingtrue
With detachable clampsfalse
Type of electric connectionScrew connection
Voltage type (supply voltage)DC
Supply voltage DC24 to 24 V
Suitable for monitoring of position switchestrue
Suitable for monitoring of emergency-stop circuitstrue
Suitable for monitoring of valvesfalse
Suitable for monitoring of optoelectronic protection equipmenttrue
Suitable for monitoring of tactile sensorsfalse
Suitable for monitoring of magnetic switchesfalse
Suitable for monitoring of proximity switchesfalse
Evaluation inputsOne- and two-channel
Power consumption2.5 W
With start inputtrue
With muting functionfalse
With feedback circuitfalse
Number of outputs, safety related, undelayed, with contact3
Number of outputs, safety related, delayed, with contact0
Number of outputs, safety related, undelayed, semiconductors1
Number of outputs, safety related, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact1
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Rated switch current6 A
Type of safety according to IEC 61496-1None
Performance level according to EN ISO 13849-1Level e
SIL according to IEC 615083
Width22.5 mm
Height98 mm
Built by rastro.ai