14 products, 455 attributes mapped across 2 ETIM classes. 79% coverage from public catalogs and spec sheets alone.

Products14

Suitable for valveYes
Suitable for air accessoryNo
Supply voltage24 V AC/DC
Control signal0 - 10 V / 4 - 20 mA
Communications protocolNone
Energy consumption in operation1.7 W
ModelLinear
Regulation type on/offYes
Regulation type modulatingYes
Regulation type splitrangeNo
TransmissionWith cogwheels
Connection to stop valveNone
With top flange direct mount according to ISO 5211No
Return at zero supply voltageNo
Deactivated when closedNo
Type of safety functionOther
Principle of operation safety functionOther
Automatic stroke recognitionYes
Adjustable position feedback signalNo
Auxiliary contactsNo
Position reporting systemNone
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeYes
With mechanical setting indicatorYes
Suitable for manual operationYes
Operating time96 s
Potential free switch contactNo
Adjusting force1000 N
Stroke length8 mm
Self-adjusting travel lengthYes
With safety functionNo
Degree of protection (IP)IP54
Max. electric power input3.5 VA
Allowable relative humidity5 to 95 %
Ambient temperature-10 to 55 °C
Height187 mm
Width160 mm
Depth88 mm
Explosion-proofNo
Housing materialPlastic
Suitable for valveYes
Suitable for air accessoryNo
Supply voltage24 V AC/DC
Control signal0 - 10 V / 4 - 20 mA
Communications protocolNone
Energy consumption in operation1.7 W
ModelLinear
Regulation type on/offYes
Regulation type modulatingYes
Regulation type splitrangeNo
TransmissionWith cogwheels
Connection to stop valveNone
With top flange direct mount according to ISO 5211No
Return at zero supply voltageNo
Deactivated when closedNo
Type of safety functionOther
Principle of operation safety functionOther
Automatic stroke recognitionYes
Adjustable position feedback signalNo
Auxiliary contactsNo
Position reporting systemNone
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeYes
With mechanical setting indicatorYes
Suitable for manual operationYes
Operating time120 s
Potential free switch contactNo
Adjusting force1000 N
Stroke length20 mm
Self-adjusting travel lengthYes
With safety functionNo
Degree of protection (IP)IP54
Max. electric power input3.5 VA
Allowable relative humidity5 to 95 %
Ambient temperature-10 to 55 °C
Height241 mm
Width160 mm
Depth88 mm
Explosion-proofNo
Housing materialPlastic
Suitable for valveYes
Suitable for air accessoryNo
Supply voltage24 V AC/DC
Control signal0 - 10 V / 4 - 20 mA
Communications protocolNone
Energy consumption in operation10 W
ModelLinear
Regulation type on/offYes
Regulation type modulatingYes
Regulation type splitrangeNo
TransmissionWith cogwheels
Connection to stop valveNone
With top flange direct mount according to ISO 5211No
Return at zero supply voltageNo
Deactivated when closedNo
Type of safety functionOther
Principle of operation safety functionOther
Automatic stroke recognitionYes
Adjustable position feedback signalYes
Auxiliary contactsNo
Position reporting system0 - 10 V
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeYes
With mechanical setting indicatorYes
Suitable for manual operationYes
Potential free switch contactNo
Adjusting force2500 N
Stroke length49 mm
Self-adjusting travel lengthYes
With safety functionNo
Degree of protection (IP)IP66
Max. electric power input20 VA
Allowable relative humidity5 to 95 %
Ambient temperature-10 to 55 °C
Height230 mm
Width117 mm
Depth289 mm
Explosion-proofNo
Housing materialOther
Suitable for valveYes
Suitable for air accessoryNo
Supply voltage24 V AC/DC
Control signal0 - 10 V / 4 - 20 mA
Communications protocolNone
Energy consumption in operation4.8 W
ModelLinear
Regulation type on/offYes
Regulation type modulatingYes
Regulation type splitrangeNo
Connection cable length1.2 m
TransmissionWith cogwheels
Connection to stop valveNone
With top flange direct mount according to ISO 5211No
Return at zero supply voltageNo
Deactivated when closedNo
Type of safety functionOther
Principle of operation safety functionOther
Automatic stroke recognitionNo
Adjustable position feedback signalNo
Auxiliary contactsNo
Position reporting systemNone
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeYes
With mechanical setting indicatorNo
Suitable for manual operationYes
Operating time60 s
Potential free switch contactNo
Adjusting force250 N
Stroke length8 mm
Self-adjusting travel lengthNo
With safety functionNo
Degree of protection (IP)IP54
Max. electric power input8.5 VA
Allowable relative humidity5 to 95 %
Ambient temperature-10 to 55 °C
Explosion-proofNo
Housing materialPlastic
Suitable for valveYes
Suitable for air accessoryNo
Supply voltage24 V AC/DC
Control signal0 - 10 V / 4 - 20 mA
Communications protocolNone
Energy consumption in operation4.9 W
ModelLinear
Regulation type on/offYes
Regulation type modulatingYes
Regulation type splitrangeNo
Connection cable length1.2 m
TransmissionWith cogwheels
Connection to stop valveNone
With top flange direct mount according to ISO 5211No
Return at zero supply voltageNo
Deactivated when closedNo
Type of safety functionOther
Principle of operation safety functionOther
Automatic stroke recognitionNo
Adjustable position feedback signalNo
Auxiliary contactsNo
Position reporting systemNone
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeYes
With mechanical setting indicatorNo
Suitable for manual operationYes
Operating time60 s
Potential free switch contactNo
Adjusting force500 N
Stroke length8 mm
Self-adjusting travel lengthNo
With safety functionNo
Degree of protection (IP)IP54
Max. electric power input8.7 VA
Allowable relative humidity5 to 95 %
Ambient temperature-10 to 55 °C
Explosion-proofNo
Housing materialPlastic
Suitable for valveYes
Suitable for air accessoryNo
Supply voltage24 V AC/DC
Control signal0 - 10 V / 4 - 20 mA
Communication busRS-485
Communications protocolOther
Energy consumption in operation4.0 W
ModelLinear
Regulation type on/offYes
Regulation type modulatingYes
Regulation type splitrangeNo
TransmissionWith cogwheels
Connection to stop valveNone
With top flange direct mount according to ISO 5211No
Return at zero supply voltageNo
Deactivated when closedNo
Type of safety functionOther
Principle of operation safety functionOther
Automatic stroke recognitionYes
Adjustable position feedback signalYes
Auxiliary contactsNo
Position reporting systemBus connection
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeYes
With mechanical setting indicatorNo
Suitable for manual operationYes
Potential free switch contactNo
Adjusting force500 N
Stroke length8 mm
Self-adjusting travel lengthYes
With safety functionNo
Degree of protection (IP)IP54
Max. electric power input7.3 VA
Allowable relative humidity5 to 95 %
Ambient temperature-10 to 55 °C
Explosion-proofNo
Housing materialPlastic
Suitable for valveYes
Suitable for air accessoryNo
Supply voltage230 V AC
Control signal2-point/3-point
Communications protocolNone
Energy consumption in operation2.0 W
ModelLinear
Regulation type on/offYes
Regulation type modulatingNo
Regulation type splitrangeNo
TransmissionWith cogwheels
Connection to stop valveM30 x 1.5
With top flange direct mount according to ISO 5211No
Return at zero supply voltageNo
Deactivated when closedNo
Type of safety functionOther
Principle of operation safety functionOther
Automatic stroke recognitionNo
Adjustable position feedback signalNo
Auxiliary contactsNo
Position reporting systemNone
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeNo
With mechanical setting indicatorYes
Suitable for manual operationNo
Operating time82 s
Potential free switch contactNo
Adjusting force120 N
Stroke length6.3 mm
Self-adjusting travel lengthNo
With safety functionNo
Degree of protection (IP)IP54
Max. electric power input6.5 VA
Explosion-proofNo
Housing materialPlastic
Suitable for valveYes
Suitable for air accessoryNo
Supply voltage24 V AC
Control signal2-point/3-point
Communications protocolNone
Energy consumption in operation1.5 W
ModelLinear
Regulation type on/offYes
Regulation type modulatingNo
Regulation type splitrangeNo
TransmissionWith cogwheels
Connection to stop valveM30 x 1.5
With top flange direct mount according to ISO 5211No
Return at zero supply voltageNo
Deactivated when closedNo
Type of safety functionOther
Principle of operation safety functionOther
Automatic stroke recognitionNo
Adjustable position feedback signalNo
Auxiliary contactsNo
Position reporting systemNone
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeNo
With mechanical setting indicatorYes
Suitable for manual operationNo
Operating time82 s
Potential free switch contactNo
Adjusting force120 N
Stroke length6.3 mm
Self-adjusting travel lengthNo
With safety functionNo
Degree of protection (IP)IP54
Max. electric power input2.5 VA
Explosion-proofNo
Housing materialPlastic
Suitable for valveYes
Suitable for air accessoryNo
Supply voltage24 V AC/DC
Control signal0 - 10 V / 4 - 20 mA
Communications protocolNone
ModelLinear
Regulation type on/offYes
Regulation type modulatingYes
Regulation type splitrangeNo
TransmissionWith cogwheels
Connection to stop valveNone
With top flange direct mount according to ISO 5211No
Return at zero supply voltageYes
Deactivated when closedNo
Type of safety functionSpring
Principle of operation safety functionNC normaly closed
Automatic stroke recognitionYes
Adjustable position feedback signalYes
Auxiliary contactsNo
Position reporting system0 - 10 V
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeYes
With mechanical setting indicatorYes
Suitable for manual operationYes
Potential free switch contactNo
Adjusting force1100 N
Stroke length49 mm
Self-adjusting travel lengthYes
With safety functionYes
Degree of protection (IP)IP66
Allowable relative humidity5 to 95 %
Ambient temperature-10 to 55 °C
Explosion-proofNo
Housing materialSteel
Suitable for valveYes
Suitable for air accessoryNo
Supply voltage230 V AC
Control signal0 - 10 V / 4 - 20 mA
Communications protocolNone
ModelLinear
Regulation type on/offYes
Regulation type modulatingYes
Regulation type splitrangeNo
TransmissionWith cogwheels
Connection to stop valveNone
With top flange direct mount according to ISO 5211No
Return at zero supply voltageYes
Deactivated when closedNo
Type of safety functionSpring
Principle of operation safety functionNC normaly closed
Automatic stroke recognitionYes
Adjustable position feedback signalYes
Auxiliary contactsNo
Position reporting system0 - 10 V
Auxiliary contacts optionalNo
End contactsNone
Adjustable operating rangeYes
With mechanical setting indicatorYes
Suitable for manual operationYes
Potential free switch contactNo
Adjusting force2500 N
Stroke length49 mm
Self-adjusting travel lengthYes
With safety functionYes
Degree of protection (IP)IP66
Allowable relative humidity5 to 95 %
Ambient temperature-10 to 55 °C
Explosion-proofNo
Housing materialOther
ModelOther
Connection to stop valveM30 x 1.5
Supply voltage230 V AC
Control signal2-point
FunctionDeactivated when closed NC
Automatic stroke recognitionNo
Protected against overvoltageNo
Auxiliary contactsNo
With end contactsNo
First openYes
With position indicatorYes
Suitable for manual operationNo
Cable length1.0 m
With valve adaptorYes
Operating time240 s
Stroke length5.0 mm
Self-adjusting travel lengthNo
ColourWhite
Degree of protection (IP)IP54
ModelOther
Connection to stop valveM30 x 1.5
Supply voltage24 V AC/DC
Control signal2-point
FunctionDeactivated when closed NC
Automatic stroke recognitionNo
Protected against overvoltageNo
Auxiliary contactsNo
With end contactsNo
First openYes
With position indicatorYes
Suitable for manual operationNo
Cable length1.0 m
With valve adaptorYes
Operating time240 s
Stroke length5.0 mm
Self-adjusting travel lengthNo
ColourWhite
Degree of protection (IP)IP54
ModelOther
Connection to stop valveM30 x 1.5
Supply voltage230 V AC
Control signal2-point
FunctionDeactivated when closed NC
Automatic stroke recognitionNo
Protected against overvoltageNo
Auxiliary contactsNo
With end contactsNo
First openYes
With position indicatorYes
Suitable for manual operationNo
Cable length1.0 m
With valve adaptorYes
Operating time270 s
Stroke length6.5 mm
Self-adjusting travel lengthNo
ColourWhite
Degree of protection (IP)IP54
ModelOther
Connection to stop valveM30 x 1.5
Supply voltage24 V AC
Control signal0 - 10 V
FunctionDeactivated when closed NC
Automatic stroke recognitionNo
Protected against overvoltageNo
Auxiliary contactsNo
With end contactsNo
First openYes
With position indicatorYes
Suitable for manual operationNo
With valve adaptorYes
Operating time195 s
Stroke length6.5 mm
Self-adjusting travel lengthNo
ColourWhite
Degree of protection (IP)IP54

Built by rastro.ai