Systemair
11 products, 720 attributes mapped across 1 ETIM class. 91% coverage from public catalogs and spec sheets alone.
Products11
Heat recovery byCross-counter-flow unit
Housing materialSteel
Housing material qualityExpanded polypropylene (EPP)
Material heat exchangerPlastic
Suitable for wall mountingYes
Suitable for ceiling mountingNo
Suitable for floor mountingNo
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa700 m³/h
Max. air volume at 100 Pa610 m³/h
Max. air volume at 150 Pa530 m³/h
Max. air volume at 200 Pa450 m³/h
Max. air volume at 250 Pa380 m³/h
Power consumption at max. air volume at 100 Pa170 W
Thermal efficiency at 70 % air volume at 50 Pa90 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device10 A
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA+
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementNo
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassYes
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionHeating element
Nominal duct diameter200-250 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideNo
Residential connection, right sideNo
Residential connection, topYes
Roof connection, sideNo
Roof connection, topYes
Max. number of wet zones8
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:201650 %
Height1720 mm
Width595 mm
Depth420 mm
Degree of protection (IP)IP22
Weight151 kg
Heat recovery byThermal wheel
Housing materialSteel
Material heat exchangerAluminium
Suitable for wall mountingYes
Suitable for ceiling mountingNo
Suitable for floor mountingNo
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa540 m³/h
Max. air volume at 100 Pa470 m³/h
Max. air volume at 150 Pa400 m³/h
Max. air volume at 200 Pa340 m³/h
Power consumption at max. air volume at 100 Pa170 W
Thermal efficiency at 70 % air volume at 50 Pa83 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device13 A
Power electric heating element1670-1670 W
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementYes
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassNo
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionOther
Nominal duct diameter200-250 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideNo
Residential connection, right sideNo
Residential connection, topYes
Roof connection, sideNo
Roof connection, topYes
Max. number of wet zones6
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:201650 %
Height1060 mm
Width595 mm
Depth470 mm
Degree of protection (IP)IP22
Weight85 kg
Heat recovery byThermal wheel
Housing materialSteel
Material heat exchangerAluminium
Suitable for wall mountingYes
Suitable for ceiling mountingYes
Suitable for floor mountingYes
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa612 m³/h
Max. air volume at 100 Pa530 m³/h
Max. air volume at 150 Pa450 m³/h
Max. air volume at 200 Pa380 m³/h
Power consumption at max. air volume at 100 Pa170 W
Thermal efficiency at 70 % air volume at 50 Pa84 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device13 A
Power electric heating element1670-1670 W
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementYes
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassNo
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionOther
Nominal duct diameter200-250 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideYes
Residential connection, right sideYes
Residential connection, topNo
Roof connection, sideYes
Roof connection, topNo
Max. number of wet zones7
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:201650 %
Height645 mm
Width1150 mm
Depth595 mm
Degree of protection (IP)IP22
Weight77 kg
Heat recovery byCross-counter-flow unit
Housing materialSteel
Housing material qualityExpanded polypropylene (EPP)
Material heat exchangerPlastic
Suitable for wall mountingYes
Suitable for ceiling mountingNo
Suitable for floor mountingNo
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa510 m³/h
Max. air volume at 100 Pa440 m³/h
Max. air volume at 150 Pa370 m³/h
Max. air volume at 200 Pa310 m³/h
Power consumption at max. air volume at 100 Pa170 W
Thermal efficiency at 70 % air volume at 50 Pa88 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device10 A
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementNo
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassYes
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionHeating element
Nominal duct diameter200-250 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideNo
Residential connection, right sideNo
Residential connection, topYes
Roof connection, sideNo
Roof connection, topYes
Max. number of wet zones6
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:201650 %
Height1380 mm
Width595 mm
Depth420 mm
Degree of protection (IP)IP22
Weight82 kg
Heat recovery byThermal wheel
Housing materialSteel
Material heat exchangerAluminium
Suitable for wall mountingYes
Suitable for ceiling mountingNo
Suitable for floor mountingNo
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa180 m³/h
Max. air volume at 100 Pa150 m³/h
Max. air volume at 150 Pa120 m³/h
Power consumption at max. air volume at 100 Pa86 W
Thermal efficiency at 70 % air volume at 50 Pa79 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device10 A
Power electric heating element500-1000 W
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementYes
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassNo
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionOther
Nominal duct diameter125-160 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideNo
Residential connection, right sideNo
Residential connection, topYes
Roof connection, sideNo
Roof connection, topYes
Max. number of wet zones3
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:201650 %
Height600 mm
Width595 mm
Depth385 mm
Degree of protection (IP)IP22
Weight46 kg
Heat recovery byThermal wheel
Housing materialSteel
Material heat exchangerAluminium
Suitable for wall mountingYes
Suitable for ceiling mountingNo
Suitable for floor mountingNo
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa270 m³/h
Max. air volume at 100 Pa230 m³/h
Max. air volume at 150 Pa190 m³/h
Power consumption at max. air volume at 100 Pa105 W
Thermal efficiency at 70 % air volume at 50 Pa80 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device10 A
Power electric heating element500-1000 W
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementYes
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassNo
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionOther
Nominal duct diameter125-200 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideNo
Residential connection, right sideNo
Residential connection, topYes
Roof connection, sideNo
Roof connection, topYes
Max. number of wet zones4
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:201650 %
Height700 mm
Width595 mm
Depth470 mm
Degree of protection (IP)IP22
Weight56 kg
Heat recovery byThermal wheel
Housing materialSteel
Material heat exchangerAluminium
Suitable for wall mountingYes
Suitable for ceiling mountingNo
Suitable for floor mountingNo
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa367 m³/h
Max. air volume at 100 Pa310 m³/h
Max. air volume at 150 Pa260 m³/h
Power consumption at max. air volume at 100 Pa88 W
Thermal efficiency at 70 % air volume at 50 Pa82 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device10 A
Power electric heating element1670-1670 W
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementYes
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassNo
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionOther
Nominal duct diameter160-200 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideNo
Residential connection, right sideNo
Residential connection, topYes
Roof connection, sideNo
Roof connection, topYes
Max. number of wet zones5
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:201650 %
Height790 mm
Width595 mm
Depth470 mm
Degree of protection (IP)IP22
Weight70 kg
Heat recovery byThermal wheel
Housing materialSteel
Material heat exchangerAluminium
Suitable for wall mountingYes
Suitable for ceiling mountingYes
Suitable for floor mountingYes
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa360 m³/h
Max. air volume at 100 Pa300 m³/h
Max. air volume at 150 Pa250 m³/h
Power consumption at max. air volume at 100 Pa83 W
Thermal efficiency at 70 % air volume at 50 Pa82 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device10 A
Power electric heating element1670-1670 W
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementYes
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassNo
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionOther
Nominal duct diameter160-200 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideYes
Residential connection, right sideYes
Residential connection, topNo
Roof connection, sideYes
Roof connection, topNo
Max. number of wet zones5
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:201650 %
Height645 mm
Width1090 mm
Depth595 mm
Degree of protection (IP)IP22
Weight65 kg
Heat recovery byThermal wheel
Housing materialSteel
Material heat exchangerAluminium
Suitable for wall mountingYes
Suitable for ceiling mountingYes
Suitable for floor mountingYes
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa480 m³/h
Max. air volume at 100 Pa410 m³/h
Max. air volume at 150 Pa350 m³/h
Power consumption at max. air volume at 100 Pa169 W
Thermal efficiency at 70 % air volume at 50 Pa83 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device13 A
Power electric heating element1670-1670 W
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementYes
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassNo
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionOther
Nominal duct diameter200-250 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideYes
Residential connection, right sideYes
Residential connection, topNo
Roof connection, sideYes
Roof connection, topNo
Max. number of wet zones6
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO ePM10
Efficiency exhaust filter according to ISO 16890-1:201650 %
Height645 mm
Width1150 mm
Depth595 mm
Degree of protection (IP)IP24
Weight80 kg
Heat recovery byCross-counter-flow unit
Housing materialSteel
Housing material qualityExpanded polypropylene (EPP)
Material heat exchangerPlastic
Suitable for wall mountingYes
Suitable for ceiling mountingNo
Suitable for floor mountingNo
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa200 m³/h
Max. air volume at 100 Pa170 m³/h
Max. air volume at 150 Pa140 m³/h
Power consumption at max. air volume at 100 Pa85 W
Thermal efficiency at 70 % air volume at 50 Pa84 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device10 A
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementNo
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassYes
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionHeating element
Nominal duct diameter125-160 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideNo
Residential connection, right sideNo
Residential connection, topYes
Roof connection, sideNo
Roof connection, topYes
Max. number of wet zones3
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO Coarse
Efficiency exhaust filter according to ISO 16890-1:201665 %
Height760 mm
Width595 mm
Depth385 mm
Degree of protection (IP)IP24
Weight47 kg
Heat recovery byCross-counter-flow unit
Housing materialSteel
Housing material qualityExpanded polypropylene (EPP)
Material heat exchangerPlastic
Suitable for wall mountingYes
Suitable for ceiling mountingNo
Suitable for floor mountingNo
Suitable for mounting in suspended ceilingNo
Suitable for mounting in an atticNo
Left/right orientation reversibleNo
Max. air volume at 50 Pa340 m³/h
Max. air volume at 100 Pa290 m³/h
Max. air volume at 150 Pa240 m³/h
Power consumption at max. air volume at 100 Pa85 W
Thermal efficiency at 70 % air volume at 50 Pa87 %
Type of motorElectronically commutated (EC)
Voltage230 V
Frequency50 Hz
Number of phases1
Fuse size of the device10 A
With thermal overload protectionYes
Electrical connectionTerminals
Energy efficiency class according to 1253/2014/EUA
Type of switchOther
With digital displayYes
With wired control unitYes
Suitable for wired control unitYes
With wireless remote controlNo
Suitable for wireless remote controlYes
Supporting protocol for ModbusYes
Operation by appYes
With zone controllerNo
Suitable for zone controllerYes
With heating elementNo
With volatile organic compound (VOC) sensorNo
Suitable for extra VOC sensorYes
With external humidity (RH) sensorNo
With internal humidity (RH) sensorYes
Suitable for (extra) humidity (RH) sensorYes
With internal carbon dioxide (CO2) sensorNo
Suitable for (extra) carbon dioxide (CO2) sensorYes
Suitable for central heating boiler connectionNo
With bypassYes
With constant pressure controlYes
With constant volume flow controlYes
Type of frost protectionHeating element
Nominal duct diameter160-200 mm
Connections outdoor air sideDuct end
Connections residential sideDuct end
Residential connection, undersideNo
Residential connection, left sideNo
Residential connection, right sideNo
Residential connection, topYes
Roof connection, sideNo
Roof connection, topYes
Max. number of wet zones5
Supply filter according to ISO 16890-1:2016ISO ePM1
Efficiency supply filter according to ISO 16890-1:201660 %
Exhaust filter according to ISO 16890-1:2016ISO Coarse
Efficiency exhaust filter according to ISO 16890-1:201665 %
Height1035 mm
Width595 mm
Depth420 mm
Degree of protection (IP)IP22
Weight72 kg